set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
set @stmt= ' explain SELECT (SELECT SUM(c1 + c12 + 0.0) FROM t2 where (t1.c2 - 0e-3) = t2.c2 GROUP BY t1.c15 LIMIT 1) as scalar_s, exists (select 1.0e+0 from t2 where t2.c3 * 9.0000000000 = t1.c4) as exists_s, c5 * 4 in (select c6 + 0.3e+1 from t2) as in_s, (c7 - 4, c8 - 4) in (select c9 + 4.0, c10 + 40e-1 from t2) as in_row_s FROM t1, (select c25 x, c32 y from t2) tt WHERE x * 1 = c25 ' ;
prepare stmt1 from @stmt ;
execute stmt1 ;
@ -177,6 +179,7 @@ id select_type table type possible_keys key key_len ref rows Extra
2 DEPENDENT SUBQUERY NULL NULL NULL NULL NULL NULL NULL Impossible WHERE noticed after reading const tables
deallocate prepare stmt1;
drop tables t1,t2;
set @@optimizer_switch=@save_optimizer_switch;
set @arg00=1;
prepare stmt1 from ' create table t1 (m int) as select 1 as m ' ;
set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
explain extended select a in (select max(ie) from t1 where oref=4 group by grp) from t3;
id select_type table type possible_keys key key_len ref rows filtered Extra
1 PRIMARY t3 ALL NULL NULL NULL NULL 2 100.00
2 DEPENDENT SUBQUERY t1 ALL NULL NULL NULL NULL 6 100.00 Using where; Using temporary; Using filesort
Warnings:
Note 1003 select <in_optimizer>(`test`.`t3`.`a`,<exists>(select max(`test`.`t1`.`ie`) AS `max(ie)` from `test`.`t1` where (`test`.`t1`.`oref` = 4) group by `test`.`t1`.`grp` having trigcond((<cache>(`test`.`t3`.`a`) = <ref_null_helper>(max(`test`.`t1`.`ie`)))))) AS `a in (select max(ie) from t1 where oref=4 group by grp)` from `test`.`t3`
set @@optimizer_switch=@save_optimizer_switch;
drop table t1, t2, t3;
create table t1 (a int, oref int, key(a));
insert into t1 values
@ -692,6 +695,8 @@ a MAX(b) test
2 3 h
3 4 i
DROP TABLE t1, t2;
set @save_optimizer_switch=@@optimizer_switch;
set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
CREATE TABLE t1 (a int);
CREATE TABLE t2 (b int, PRIMARY KEY(b));
INSERT INTO t1 VALUES (1), (NULL), (4);
@ -759,6 +764,7 @@ id select_type table type possible_keys key key_len ref rows Extra
1 PRIMARY t1 ALL NULL NULL NULL NULL 4 Using where
2 DEPENDENT SUBQUERY t2 unique_subquery PRIMARY PRIMARY 4 func 1 Using index; Using where
set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
explain extended select a in (select max(ie) from t1 where oref=4 group by grp) from t3;
id select_type table type possible_keys key key_len ref rows filtered Extra
1 PRIMARY t3 ALL NULL NULL NULL NULL 2 100.00
2 DEPENDENT SUBQUERY t1 ALL NULL NULL NULL NULL 6 100.00 Using where; Using temporary; Using filesort
Warnings:
Note 1003 select <in_optimizer>(`test`.`t3`.`a`,<exists>(select max(`test`.`t1`.`ie`) AS `max(ie)` from `test`.`t1` where (`test`.`t1`.`oref` = 4) group by `test`.`t1`.`grp` having trigcond((<cache>(`test`.`t3`.`a`) = <ref_null_helper>(max(`test`.`t1`.`ie`)))))) AS `a in (select max(ie) from t1 where oref=4 group by grp)` from `test`.`t3`
set @@optimizer_switch=@save_optimizer_switch;
drop table t1, t2, t3;
create table t1 (a int, oref int, key(a));
insert into t1 values
@ -696,6 +699,8 @@ a MAX(b) test
2 3 h
3 4 i
DROP TABLE t1, t2;
set @save_optimizer_switch=@@optimizer_switch;
set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
CREATE TABLE t1 (a int);
CREATE TABLE t2 (b int, PRIMARY KEY(b));
INSERT INTO t1 VALUES (1), (NULL), (4);
@ -763,6 +768,7 @@ id select_type table type possible_keys key key_len ref rows Extra
1 PRIMARY t1 ALL NULL NULL NULL NULL 4 Using where
2 DEPENDENT SUBQUERY t2 unique_subquery PRIMARY PRIMARY 4 func 1 Using index; Using where
set @@optimizer_switch="partial_match_rowid_merge=off,partial_match_table_scan=off";
set @stmt= ' explain SELECT (SELECT SUM(c1 + c12 + 0.0) FROM t2 where (t1.c2 - 0e-3) = t2.c2 GROUP BY t1.c15 LIMIT 1) as scalar_s, exists (select 1.0e+0 from t2 where t2.c3 * 9.0000000000 = t1.c4) as exists_s, c5 * 4 in (select c6 + 0.3e+1 from t2) as in_s, (c7 - 4, c8 - 4) in (select c9 + 4.0, c10 + 40e-1 from t2) as in_row_s FROM t1, (select c25 x, c32 y from t2) tt WHERE x * 1 = c25 ' ;
prepare stmt1 from @stmt ;
execute stmt1 ;
@ -171,6 +174,8 @@ explain SELECT (SELECT SUM(c1 + c12 + 0.0) FROM t2 where (t1.c2 - 0e-3) = t2.c2
"Each thread that does a sequential scan allocates a buffer of this size for each table it scans. If you do many sequential scans, you may want to increase this value.",