This allows us to make the various netlist and pcb update routines
more atomic and less reliant on carefully sequenced asynchronous
messages.
This is also a prelude to adding support for footprint testing
without a netlist.
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
It can be useful to have similar class messages grouped together so that
error messages in a larger report don't get lost among the
warning/info/action messages.
This patch allows sorting of messages for dialogs that benefit from
organization. Default behavior of reporter messages remains
unchanged by this patch.
Fixes: lp:1772090
* https://bugs.launchpad.net/kicad/+bug/1772090
This also makes the dialog modeless so that one switch between
sheets while annotating to choose the base numbers for each
sheet (assuming they don't like the base number we pick because
of the order of the sheets).
Fixes: lp:1154131
* https://bugs.launchpad.net/kicad/+bug/1154131
Also fixes:
- forcing the annotation scope to "full schematic" when run
as a prerequisite to Generate Netlist.
- a long-standing bug where displaying extra items in a dialog
would mess up the height of the HTML_REPORT_PANEL (becasue
we were setting the html window's height rather than its
parent flexgrid.
- initializing the annotation radio buttons to safe values
(full schematic and keep existing)
Fixes: lp:1750062
* https://bugs.launchpad.net/kicad/+bug/1750062
Simplify some of the library editing code. There have been a few minor
changes in the behavior of the editor. If the current symbol is deleted
from the library, the next symbol in the library is not loaded. The
deleted symbol is cleared and the current symbol is empty.
Change component to symbol to align with the preferred terminology
discussed on the developer's mailing list.
Add separate update UI event for save library as to enable the menu entry
whenever a library is selected.
Change the select symbol list dialog to a single column using the LIB_ID
format LIB_NICKNAME:LIB_ITEM_NAME so that the selection can be parsed by
LIB_ID.
Add method to expand URI to LIB_TABLE_BASE.
Override wxApp::OnExceptionInMainLoop() in debug builds to make debugging
easier when an unhandled exception occurs in a wxUpdateUIEvent handler.
Change SCH_SCREENS::HasNoFullyDefinedLibIds() to return false when the
schematic has no symbols to prevent the remapping dialog from being run.
Use SCH_COMPONENT part reference when creating netlist rather than looking
up the library symbol.
* Remove global s_NetObjectslist.
* Separate out non-owning version of NETLIST_OBJECTS_LIST into NETLIST_OBJECTS.
* Fix double free pertaining to ~NETLIST_READER().
* Remove all file-io from CvPCB.
* Remove exe launcher cvpcb, retain only cvpcb.kiface, since cvpcb.kiface has no file i/o.
* Add void CVPCB_MAINFRAME::KiwayMailIn( KIWAY_EXPRESS& mail ) and teach it to use old
netlist loading code with a STRING_LINE_READER LINE_READER.
* Fix BEGIN_EVENT_TABLE( CVPCB_MAINFRAME, KIWAY_PLAYER )
* move not shared files (sch_item_struct.*, sch_base_frame.h) to eeschema;
* move wxEeschemaStruct.h to eeschema and rename it schframe.h to be consistent with the other corresponding file name schframe.cpp;
* remove few not needed #include
- the net file now has all project sheet title block using node 'sheets' and 'sheet'
- Updated bom_with_title_block_2_csv. Note, its only going to output the root title block.
- corrected the code that violated the code policy. i.e. added the extra space to make the code more readable
- Restored bom2csv.xsl to its original form
- Added bom_with_title_block_2_csv.xsl which has the new BOM generator.
For example:
- Company name
- Project title
- issue date
- Revision
- Comment 1 to 4
- updated bom2csv.xsl plugin to take advatage of the extra project information that the net file now outputs.
Overall this improvement will make it easier to automatically make controlled and traceable documents.
BOM dialog: remove a not very useful button, and merge its function with an other (not perfect, need more work)
Add message box to show info added in BOM python scripts (See scripts/bom-in-python/README-bom.txt about this info)
*) When kicad.exe closes a project, close any open KIFACEs so that they cannot
get disassociated from their true PROJECT.
*) Allow loading eeschema library editor from kicad.exe
*) Allow loading pcbnew library editor from kicad.exe
*) Rename LIB_COMPONENT to LIB_PART.
*) Add class PART_LIBS, and PART_LIB.
*) Make PART_LIBS non-global, i.e. PROJECT specific.
*) Implement "data on demand" for PART_LIBS
*) Implement "data on demand" for schematic SEARCH_STACK.
*) Use RSTRINGs to retain eeschema editor's notion of last library and part being edited.
*) Get rid of library search on every SCH_COMPONENT::Draw() call, instead use
a weak pointer.
*) Remove all chdir() calls so projects don't need to be CWD.
*) Romove APPEND support from OpenProjectFiles().
*) Make OpenProjectFiles() robust, even for creating new projects.
*) Load EESCHEMA colors in the KIWAY::OnKiwayStart() rather in window open,
and save them in the .eeschema config file, not in the project file.
*) Fix bug with wxDir() while accessing protected dirs in kicad.exe
*) Consolidate template copying into PROJECT class, not in kicad.exe source.
*) Generally untangle eeschema, making its libraries not global but rather
held in the PROJECT.
was used locally. Then comment it out in favor of a newer strategy for
filling in nicknames in cvpcb.
Add MODULE* FootprintLoadWithOptionalNickname( const FPID& aFootprintId )
throw( IO_ERROR, PARSE_ERROR );
from code found elsewhere.
! The initial testing of this commit should be done using a Debug build so that
all the wxASSERT()s are enabled. Also, be sure and keep enabled the
USE_KIWAY_DLLs option. The tree won't likely build without it. Turning it
off is senseless anyways. If you want stable code, go back to a prior version,
the one tagged with "stable".
* Relocate all functionality out of the wxApp derivative into more finely
targeted purposes:
a) DLL/DSO specific
b) PROJECT specific
c) EXE or process specific
d) configuration file specific data
e) configuration file manipulations functions.
All of this functionality was blended into an extremely large wxApp derivative
and that was incompatible with the desire to support multiple concurrently
loaded DLL/DSO's ("KIFACE")s and multiple concurrently open projects.
An amazing amount of organization come from simply sorting each bit of
functionality into the proper box.
* Switch to wxConfigBase from wxConfig everywhere except instantiation.
* Add classes KIWAY, KIFACE, KIFACE_I, SEARCH_STACK, PGM_BASE, PGM_KICAD,
PGM_SINGLE_TOP,
* Remove "Return" prefix on many function names.
* Remove obvious comments from CMakeLists.txt files, and from else() and endif()s.
* Fix building boost for use in a DSO on linux.
* Remove some of the assumptions in the CMakeLists.txt files that windows had
to be the host platform when building windows binaries.
* Reduce the number of wxStrings being constructed at program load time via
static construction.
* Pass wxConfigBase* to all SaveSettings() and LoadSettings() functions so that
these functions are useful even when the wxConfigBase comes from another
source, as is the case in the KICAD_MANAGER_FRAME.
* Move the setting of the KIPRJMOD environment variable into class PROJECT,
so that it can be moved into a project variable soon, and out of FP_LIB_TABLE.
* Add the KIWAY_PLAYER which is associated with a particular PROJECT, and all
its child wxFrames and wxDialogs now have a Kiway() member function which
returns a KIWAY& that that window tree branch is in support of. This is like
wxWindows DNA in that child windows get this member with proper value at time
of construction.
* Anticipate some of the needs for milestones B) and C) and make code
adjustments now in an effort to reduce work in those milestones.
* No testing has been done for python scripting, since milestone C) has that
being largely reworked and re-thought-out.
Fix an annoying issue about not named nets:
now, these nets are named from the component references and pin names which are connected.
therefore, unless the net or the footprint references are modified, the net name is not modified between 2 netlist calculations.
* Complete encapsulation of the MODULE class.
* Complete encapsulation of the EDA_TEXT class.
* Encapsulate most of the ZONE_CONTAINER class.
* Add pcbcommon library as a dependency for reSWIGging the scripting
support. This should cover most dependency cases.